product details Integrating the essence of mechanical design with the wisdom of electrical research and development
■ BSQ9950A/BSQ9951A/BSQ9952A are voltage insulation testers designed for testing finished photovoltaic modules, and can also be used for wet leakage testing of modules. The maximum output of the instrument is DC 15kV, and the maximum testing range of insulation resistance is 99G Ω. The instrument is equipped with RS232 serial port, which can achieve data transmission and acquisition functions. The testing equipment meets the insulation test, withstand voltage test, and insulation resistance test requirements in IEC61215:2021 MQT03 and IEC61730-2:2016 MST04 standards.
Performance parameterPerformance parameter
Equipment model
|
BSQ9951A
|
BSQ9952A
|
BSQ9953A
|
DCW(Voltage resistant function)
|
Rated Output
|
10KV DC/5.00mA
|
15KV DC/5.00mA
|
15KV DC/5.00mA
|
Voltage Output DC
|
0 - 10KV
|
0 - 15KV
|
0 - 15KV
|
Voltage resolution DC
|
1V
|
1V
|
1V
|
Voltage accuracy VDC
|
± (1.5% set value +5V)
|
± (1.5% set value +5V)
|
± (1.5% set value +5V)
|
Upper limit current DC,
|
0.01mA arrive 5.00mA
|
0.01mA arrive 5.00mA
|
0.01mA arrive 5.00mA
|
Lower limit current DC
|
0.01mA arrive 5.00mA
|
0.01mA arrive 5.00mA
|
0.01mA arrive 5.00mA
|
Current resolution DC
|
0.01mA
|
0.01mA
|
0.01mA
|
Current accuracy DC
|
士(1% set value+2 words)
|
士(1% set value+2 words)
|
士(1% set value+2 words)
|
Rise time setting
|
0.1 - 999.9S
|
0.1 - 999.9S
|
0.1 - 999.9S
|
Duration setting
|
0, 0.4 - 999.9 (0=Continuous testing)
|
0, 0.4 - 999.9 (0=Continuous testing)
|
0, 0.4 - 999.9 (0=Continuous testing)
|
Temporal resolution
|
0.1S
|
0.1S
|
0.1S
|
time accuracy
|
±(0.1%The set value+0.05 S)
|
±(0.1%The set value+0.05 S)
|
±(0.1%The set value+0.05 S)
|
IR(Insulation function)
|
Rated Output
|
3KV DC/2mA
|
3KV DC/2mA
|
6KV DC/2mA
|
Voltage Output KVDC
|
0.01KV arrive 3.00KV
|
0.01KV arrive 3.00KV
|
0.01KV arrive 6.00KV
|
Voltage resolution VDC
|
10V
|
10V
|
10V
|
Voltage accuracy VDC
|
士(3%set value+5V)
|
士(3%set value+5V)
|
士(3%set value+5V)
|
Upper limit resistance, GΩ
|
100KΩ arrive 99GΩ
|
100KΩ arrive 99GΩ
|
100KΩ arrive 99GΩ
|
Lower limit resistance, GΩ
|
100KΩ arrive 99GΩ
|
100KΩ arrive 99GΩ
|
100KΩ arrive 99GΩ
|
Display mode
|
100 KΩ~999KΩ;1.00MΩ~9.99MΩ;10.0MΩ~99.9MΩ;100MΩ~999MΩ;1.00GΩ~9.99GΩ;10GΩ~99GΩ;
|
100 KΩ~999KΩ;1.00MΩ~9.99MΩ;10.0MΩ~99.9MΩ;100MΩ~999MΩ;1.00GΩ~9.99GΩ;10GΩ~99GΩ;
|
100 KΩ~999KΩ;1.00MΩ~9.99MΩ;10.0MΩ~99.9MΩ;100MΩ~999MΩ;1.00GΩ~9.99GΩ;10GΩ~99GΩ;
|
Resistance Accuracy
|
±(1% display value+3 words) 100KΩ≤R≤9.99GΩ;
±(10%The displayed value+3 个字) 10GΩ≤R≤99GΩ;
(When there is no swing in the test line)
|
±(1% display value+3 words) 100KΩ≤R≤9.99GΩ;
±(10% display value+3 words) 10GΩ≤R≤99GΩ;
(When there is no swing in the test line)
|
±(1% display value+3 words) 100KΩ≤R≤9.99GΩ;
±(10% display value+3 words) 10GΩ≤R≤99GΩ;
(When there is no swing in the test line)
|
Rise time setting
|
0.1 - 999.9S
|
0.1 - 999.9S
|
0.1 - 999.9S
|
Duration setting
|
0, 0.4 - 999.9
|
0, 0.4 - 999.9
|
0, 0.4 - 999.9
|
Temporal resolution
|
0.1S
|
0.1S
|
0.1S
|
time accuracy
|
±(0.1% set value+0.05 S)
|
±(0.1% set value+0.05 S)
|
±(0.1% set value+0.05 S)
|
Memory group
|
6 groups
|
communication interface
|
Handler,RS232,RS485(Optional)
|
power supply
|
voltage:198VAC~240VAC,frequency:47HZ-63HZ;rated power:100VA
|
size
|
W386mm*D280mm*H99mm;weight:7.5kG
|
W349mm*D398mm*H129mm;weight:10.5kG
|
attachment
|
Power line, high voltage output line
|
Sales records of the same type of equipmentSales records of the same type of equipment
|
Accumulated sales quantity>100 sets
|